The distance between the TD-units. It is measured and entered by the operator, in millimeters or inch, depending on system setup.
The distance between the TD-M and the front foot of the moveable macihne. It is measured and entered by the operator, in millimeters or inch, depending on system setup.
The distance between the front foot and the rear foot of the moveable macihne. It is measured and entered by the operator, in millimeters or inch, depending on system setup. If the machine has more than four feet, the outer pairs are used.
The live value from the TD-S unit. Comparable to dial indicator value.
The live value from the TD-M unit. Comparable to dial indicator value.
The angular error expressed in mm/100mm or mils/inch.
The position of the front feet relative to ideal position. Displayed in millimeters or mils depending on system setup.
The position of the front feet relative to ideal position. Displayed in millimeters or mils depending on system setup.
Starts remeasuring of all positons.
Changes the display to show horizontal view
Opens Application setup menu.
Saves the measurement result to the memory.
Print out the currently displayed screen on the connected printer.
Exits the program.
Connector for TD-unit and/or laser transmitter.
Battery low indicator.
Turn on the system.
Operation indicator.